Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 257T 5346W 20.8J/T
Price
9 $/T
2,313 $/Unit
Shipping Date
Shipping in February-March
Payment Method
USDBTCETCUSDT(ERC20/TRC20)

$2313.00
View cart

  • Categories: Bitcoin Miner, BTC/BCH/BSV
  • Availability: In Stock
  • Product Type: Simple

Guaranteed safe & secure checkout

Performance Curves


1. Hashrate vs. Inlet Coolant Temperature

2. Power Efficiency vs. Inlet Coolant Temperature

(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

| Specifications


 

Product Glance Value
Model S19 XP Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(2-1) 257
Power on wall @35°C(2-2), Watt(2-1) 5346
Power efficiency on wall @35°C(2-2), J/T(2-1) 20.8
Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(3-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Network connection mode RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm 410*170*209
Server size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment Requirements
Inlet coolant temperature, ℃ 20~40
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(3-2) Antifreeze/ Pure water/Deionized water
Coolant  pH value
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized wate: 8.5~9.5
Diameter of coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10%~90%

Notes:

(2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.

(2-2) Inlet water temperature.

(3-1) Caution: Wrong input voltage may cause server damaged.

(3-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

Performance Curves

1. Hashrate vs. Inlet Coolant Temperature

2. Power Efficiency vs. Inlet Coolant Temperature

(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

| Specifications
 
Product Glance Value
Model S19 XP Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(2-1) 257
Power on wall @35°C(2-2), Watt(2-1) 5346
Power efficiency on wall @35°C(2-2), J/T(2-1) 20.8
Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(3-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Network connection mode RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm 410*170*209
Server size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment Requirements
Inlet coolant temperature, ℃ 20~40
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(3-2) Antifreeze/ Pure water/Deionized water
Coolant  pH value
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized wate: 8.5~9.5
Diameter of coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10%~90%
Notes: (2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%. (2-2) Inlet water temperature. (3-1) Caution: Wrong input voltage may cause server damaged. (3-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!
0

Reviews

5
0
4
0
3
0
2
0
1
0
Be the first to review “Bitcoin Miner S19 XP Hyd.”

Leave a Reply

Your email address will not be published. Required fields are marked *

Compare similar items

Find and select products to see the differences and similarities between them

Customer Rating

(0)

(0)

(0)

(0)

Price
$2313.00
$7740.00
$180000.00
$16000.00
Item Dimensions
N/A
N/A
N/A
N/A
Special Features
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 257T 5346W 20.8J/T
Price
9 $/T
2,313 $/Unit
Shipping Date
Shipping in February-March
Payment Method
USDBTCETCUSDT(ERC20/TRC20)
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 860T 11180W 13J/T
Price
9 $/T
7,740 $/Unit
Shipping Date
SPOT Shipping from October 2026
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20
Specifications 1Set 1000kW 160 Rack Space
Price
180,000 $/Unit
Shipping Date
SPOT Shipping in 60 working days after fully paid
Payment Method
USDBTCETCUSDT(ERC20/TRC20)
Specifications 1Set 200kW 20 units ANTMINER (U2 Hydro)
Price
16,000 $/Unit
Shipping Date
SPOT Shipping from November 2026
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
Weight
N/A
N/A
N/A
N/A
Availability

In stock

In stock

In stock

In stock