AR1904
| Specifications | 1028T 32kW I 4 S19 XP Hyd. and Rack I 80℃ Heating Capacity |
| Price |
9,916 $/Package
|
- Categories: Bitcoin Miner, BTC/BCH/BSV
- Availability: In Stock
- Product Type: Simple
| Specifications for AR1904
| Product Glance | Value |
| Model | ANTRACK |
| Version | AR22 |
| Capacity | 4 units ANTMINER (Hydro) or 2 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro) |
| Miner maximum load,kW | 24 |
| Total load,kW | 32 |
| Detailed Characteristics | Value |
| Part 1: Mining Cabinet | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1200*600*1200 |
| Size (Length*Width*Height), mm (with package) | 1460*780*1330 |
| Net weight, kg (without package) | 132 |
| Gross weight, kg (with package) | 193 |
| Network connection mode | RJ45 Ethernet 10/100M |
| Power Supply | |
| Power supply AC Input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC Input Frequency Range, Hz | 50~60 |
| Power supply AC Input current, Amp(1-2) | 63 |
| Water pump | |
| Rated power, W | 450 |
| Noise, dBA@1m | 60 |
| Lift, m | 19 |
| Size (Length*Width* Height), mm | 360*210*268 |
| Plate heat exchanger | |
| Maximum heat exchange power, kW | 30 |
| Size (Length*Width*Height), mm | 305*106*64 |
| Diameter of water pipe connector, mm | DN20 |
| Part 2: External Cooler(1-3) | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1370*555*1333 |
| Size (Length*Width*Height), mm (with package) | 1500*610*1880 |
| Net weight, kg (without package) | 225 |
| Gross weight, kg (with package) | 263 |
| Power supply | |
| Power supply AC input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC input frequency range, Hz | 50~60 |
| Maximum power supply AC input current, Amp(1-2) | 21 |
| Heat pump | |
| Heating Capacity(typical), kW | 32 |
| Compressor Input(typical), kW | 8 |
| EER(typical) | 3.0 |
| Sound Level, dB(A) | 50 |
| Refrigerant | R290 |
| Heating water outlet temperature, °C | 80 |
| Fan | |
| Rated power, W | 500 |
| Noise, dBA@1m | 50 |
| Size (Length*Height*Thickness), mm | 551*551*160 |
| Water pump | |
| Rated power, W | 180 |
| Noise, dBA@1m | 30 |
| Size (Length*Widht*Height), mm | 130*551*129 |
| Environment Requirements | |
| Ambient temperature, °C | -20~40 |
| Water flow, L/min | 32.0~40.0(Cabinet side) |
| Water flow, L/min | 32.0~40.0(Heating side) |
| Water pressure, bar | ≤3.5 |
| Working fluid(1-4) | Organic Antifreeze (10%) |
| Installation distance, m(1-5) | 5 |
| Liquid PH | 7.8~8.5 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10~90% |
Notes:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.
(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
(1-5) The distance between mining cabinet and external cooler.
| Specification Details For S19 XP Hyd.
| Product Glance | |
| Model | S19 XP Hyd. |
| Version | 10 |
| Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
| Typical hashrate, TH/s(1-1) | 257 |
| Power on wall @35°C(1-2), Watt(1-1) | 5,346 |
| Power efficiency on wall @35°C(1-2), J/TH(1-1) | 20.8 |
| Detailed Characteristics | |
| Power Supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input Frequency Range, Hz | 50~60 |
| Input max current, Amp | 12 |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100M |
| Server Size (Length*Width*Height, w/o package), mm | 410*170*209 |
| Server Size (Length*Width*Height, with package), mm | 570*316*430 |
| Net weight, kg(2-2) | 12.8 |
| Gross weight, kg | 14.1 |
| Environment Requirements | |
| Inlet coolant temperature,°C | 20~40 |
| Coolant flow, L/min | 8.0~10.0 |
| Coolant pressure, bar | ≤3.5 |
| Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
| Coolant pH value | Antifreeze: 7.0~9.0
Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
| Diameter of coolant pipe connector, mm | OD10 |
| Storage temperature,°C | -20~70 |
| Operation humidity(non-condensing) , RH | 10~90% |
NOTE:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values.The actual hashrate value fluctuates by ± 3%, and the actual power on wall and powerefficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HW7 Liquid cooling container & Dry-cooling Tower product manual”, Chapter 9, Article 3, Point 6, “Coolant Maintenance”!
PS: Please note that the Hydro-cooling miners are shipped without power cables. There are power cables inside the ANTRACK.
| Product Glance | Value |
| Model | ANTRACK |
| Version | AR22 |
| Capacity | 4 units ANTMINER (Hydro) or 2 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro) |
| Miner maximum load,kW | 24 |
| Total load,kW | 32 |
| Detailed Characteristics | Value |
| Part 1: Mining Cabinet | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1200*600*1200 |
| Size (Length*Width*Height), mm (with package) | 1460*780*1330 |
| Net weight, kg (without package) | 132 |
| Gross weight, kg (with package) | 193 |
| Network connection mode | RJ45 Ethernet 10/100M |
| Power Supply | |
| Power supply AC Input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC Input Frequency Range, Hz | 50~60 |
| Power supply AC Input current, Amp(1-2) | 63 |
| Water pump | |
| Rated power, W | 450 |
| Noise, dBA@1m | 60 |
| Lift, m | 19 |
| Size (Length*Width* Height), mm | 360*210*268 |
| Plate heat exchanger | |
| Maximum heat exchange power, kW | 30 |
| Size (Length*Width*Height), mm | 305*106*64 |
| Diameter of water pipe connector, mm | DN20 |
| Part 2: External Cooler(1-3) | |
| Hardware Configuration | |
| Size (Length*Width*Height), mm (without package) | 1370*555*1333 |
| Size (Length*Width*Height), mm (with package) | 1500*610*1880 |
| Net weight, kg (without package) | 225 |
| Gross weight, kg (with package) | 263 |
| Power supply | |
| Power supply AC input voltage, Volt(1-1) | 380~415V AC |
| Power supply AC input frequency range, Hz | 50~60 |
| Maximum power supply AC input current, Amp(1-2) | 21 |
| Heat pump | |
| Heating Capacity(typical), kW | 32 |
| Compressor Input(typical), kW | 8 |
| EER(typical) | 3.0 |
| Sound Level, dB(A) | 50 |
| Refrigerant | R290 |
| Heating water outlet temperature, °C | 80 |
| Fan | |
| Rated power, W | 500 |
| Noise, dBA@1m | 50 |
| Size (Length*Height*Thickness), mm | 551*551*160 |
| Water pump | |
| Rated power, W | 180 |
| Noise, dBA@1m | 30 |
| Size (Length*Widht*Height), mm | 130*551*129 |
| Environment Requirements | |
| Ambient temperature, °C | -20~40 |
| Water flow, L/min | 32.0~40.0(Cabinet side) |
| Water flow, L/min | 32.0~40.0(Heating side) |
| Water pressure, bar | ≤3.5 |
| Working fluid(1-4) | Organic Antifreeze (10%) |
| Installation distance, m(1-5) | 5 |
| Liquid PH | 7.8~8.5 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10~90% |
| Product Glance | |
| Model | S19 XP Hyd. |
| Version | 10 |
| Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
| Typical hashrate, TH/s(1-1) | 257 |
| Power on wall @35°C(1-2), Watt(1-1) | 5,346 |
| Power efficiency on wall @35°C(1-2), J/TH(1-1) | 20.8 |
| Detailed Characteristics | |
| Power Supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input Frequency Range, Hz | 50~60 |
| Input max current, Amp | 12 |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100M |
| Server Size (Length*Width*Height, w/o package), mm | 410*170*209 |
| Server Size (Length*Width*Height, with package), mm | 570*316*430 |
| Net weight, kg(2-2) | 12.8 |
| Gross weight, kg | 14.1 |
| Environment Requirements | |
| Inlet coolant temperature,°C | 20~40 |
| Coolant flow, L/min | 8.0~10.0 |
| Coolant pressure, bar | ≤3.5 |
| Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
| Coolant pH value | Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
| Diameter of coolant pipe connector, mm | OD10 |
| Storage temperature,°C | -20~70 |
| Operation humidity(non-condensing) , RH | 10~90% |

Be the first to review “AR1904”
Compare similar items
|
|
|
|
|
|||||||||||||||||||
|
Find and select products to see the differences and similarities between them |
||||||||||||||||||||||
| Customer Rating |
|
|
|
|
||||||||||||||||||
| Price |
$9916.00 |
$20000.00 |
$2400.00 |
$16000.00 |
||||||||||||||||||
| Item Dimensions |
N/A
|
N/A
|
N/A
|
N/A
|
||||||||||||||||||
| Special Features |
Shipping Date
SPOT Shipping in 7 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
|
Shipping Date
SPOT Shipping from November 2026
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
|
Shipping Date
SPOT Shipping in 7 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
|
Shipping Date
SPOT Shipping from November 2026
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
|
||||||||||||||||||
| Weight |
N/A
|
N/A
|
N/A
|
N/A
|
||||||||||||||||||
| Availability |
In stock |
In stock |
In stock |
In stock |