AR1903
AR1903

Register to buy Grocery's at wholesale prices for your shop

Bitcoin Miner

AR1903

Specifications 1028T 24kW I 4 S19 XP Hyd. and Rack I 45℃ Heating Capacity
Price
3,916 $/Package
Shipping Date
SPOT Shipping in 10 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)

$3916.00
View cart

  • Categories: Bitcoin Miner, BTC/BCH/BSV
  • Availability: In Stock
  • Product Type: Simple

Guaranteed safe & secure checkout

| Specifications for AR1903


 

Product Glance Value
Model ANTRACK
Version AR21
Capacity 4 units ANTMINER (Hydro) or
2 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro)
Maximum load,kW 24
Total load,kW 26

 

Detailed Characteristics Value
Part 1: Mining Cabinet
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1260*600*1185
Size (Length*Width*Height), mm (with package) 1320*760*1320
Net weight, kg (without package) 138
Gross weight, kg (with package) 195
Network connection mode RJ45 Ethernet 10/100M
Power Supply
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump
Rated power, W 450
Noise, dBA@1m 60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Part 2: External Cooler(1-3)
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1197*650*1177
Size (Length*Width*Height), mm (with package) 1320*760*1320
Net weight, kg (without package) 112
Gross weight, kg (with package) 165
Power supply
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 63
Fan
Rated power, W 750
Noise, dBA@1m 60
Size (Length*Height*Thickness), mm 850*850*305
Environment Requirements
Ambient temperature, °C -20~45
Water flow, L/min 32.0~40.0
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 5
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(1-1) Caution: Wrong input voltage may probably cause miner damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.

 

| Specification Details For S19 XP Hyd.


Product Glance
Model S19 XP Hyd.
Version 10
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(1-1) 257
Power on wall @35°C(1-2), Watt(1-1) 5,346
Power efficiency on wall @35°C(1-2), J/TH(1-1) 20.8
Detailed Characteristics
Power Supply
Phase 3
Input voltage, Volt(2-1) 380~415
Input Frequency Range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Networking connection mode RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm 410*170*209
Server Size (Length*Width*Height, with package), mm 570*316*430
Net weight, kg(2-2) 12.8
Gross weight, kg 14.1
Environment Requirements
Inlet coolant temperature,°C 20~40
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(2-2) Antifreeze/ Pure water/Deionized water
Coolant pH value Antifreeze: 7.0~9.0

Prue water: 6.5~7.5

Deionized water:8.5~9.5

Diameter of coolant pipe connector, mm OD10
Storage temperature,°C -20~70
Operation humidity(non-condensing) , RH 10~90%

NOTE:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values.The actual hashrate value fluctuates by ± 3%, and the actual power on wall and powerefficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HW7 Liquid cooling container & Dry-cooling Tower product manual”, Chapter 9, Article 3, Point 6, “Coolant Maintenance”!

PS: Please note that the Hydro-cooling miners are shipped without power cables. There are power cables inside the ANTRACK.

| Specifications for AR1903
 
Product Glance Value
Model ANTRACK
Version AR21
Capacity 4 units ANTMINER (Hydro) or 2 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro)
Maximum load,kW 24
Total load,kW 26
 
Detailed Characteristics Value
Part 1: Mining Cabinet
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1260*600*1185
Size (Length*Width*Height), mm (with package) 1320*760*1320
Net weight, kg (without package) 138
Gross weight, kg (with package) 195
Network connection mode RJ45 Ethernet 10/100M
Power Supply
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump
Rated power, W 450
Noise, dBA@1m 60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Part 2: External Cooler(1-3)
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1197*650*1177
Size (Length*Width*Height), mm (with package) 1320*760*1320
Net weight, kg (without package) 112
Gross weight, kg (with package) 165
Power supply
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 63
Fan
Rated power, W 750
Noise, dBA@1m 60
Size (Length*Height*Thickness), mm 850*850*305
Environment Requirements
Ambient temperature, °C -20~45
Water flow, L/min 32.0~40.0
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 5
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%
Notes: (1-1) Caution: Wrong input voltage may probably cause miner damaged. (1-2) Three-phase AC input. (1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment. (1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time. (1-5) The distance between mining cabinet and external cooler.   | Specification Details For S19 XP Hyd.
Product Glance
Model S19 XP Hyd.
Version 10
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(1-1) 257
Power on wall @35°C(1-2), Watt(1-1) 5,346
Power efficiency on wall @35°C(1-2), J/TH(1-1) 20.8
Detailed Characteristics
Power Supply
Phase 3
Input voltage, Volt(2-1) 380~415
Input Frequency Range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Networking connection mode RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm 410*170*209
Server Size (Length*Width*Height, with package), mm 570*316*430
Net weight, kg(2-2) 12.8
Gross weight, kg 14.1
Environment Requirements
Inlet coolant temperature,°C 20~40
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(2-2) Antifreeze/ Pure water/Deionized water
Coolant pH value Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water:8.5~9.5
Diameter of coolant pipe connector, mm OD10
Storage temperature,°C -20~70
Operation humidity(non-condensing) , RH 10~90%
NOTE: (1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values.The actual hashrate value fluctuates by ± 3%, and the actual power on wall and powerefficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HW7 Liquid cooling container & Dry-cooling Tower product manual", Chapter 9, Article 3, Point 6, "Coolant Maintenance"! PS: Please note that the Hydro-cooling miners are shipped without power cables. There are power cables inside the ANTRACK.
0

Reviews

5
0
4
0
3
0
2
0
1
0
Be the first to review “AR1903”

Leave a Reply

Your email address will not be published. Required fields are marked *

Compare similar items

Find and select products to see the differences and similarities between them

Customer Rating

(0)

(0)

(0)

(0)

Price
$3916.00
$29580.00
$2864.00
$1728.00
Item Dimensions
N/A
N/A
N/A
N/A
Special Features
Specifications 1028T 24kW I 4 S19 XP Hyd. and Rack I 45℃ Heating Capacity
Price
3,916 $/Package
Shipping Date
SPOT Shipping in 10 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 1160T 11020W 9.5J/T
Price
30 $/T
34,800 $/Unit
After Coupon
25.5 $/T
29,580 $/Unit
Shipping Date
Sold Out Shipping from Q3 2026
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 358T 5370W 15J/T
Price
8 $/T
2,864 $/Unit
Shipping Date
SPOT Shipping in 7 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 288T 4896W 17J/T
Price
6 $/T
1,728 $/Unit
Shipping Date
SPOT Shipping in 20 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC2
Weight
N/A
N/A
N/A
N/A
Availability

In stock

In stock

In stock

In stock