Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 251T 5522W 22J/T
Price
11 $/T
2,761 $/Unit
Shipping Date
Shipping in 10 working days after fully paid
Payment Method
USDBTCUSDT(ERC20/TRC20)

$2761.00
View cart

  • Categories: Bitcoin Miner, BTC/BCH/BSV
  • Availability: In Stock
  • Product Type: Simple

Guaranteed safe & secure checkout

| Performance Curves


 

1. Hashrate vs. Inlet Coolant Temperature

 

2. Power Efficiency vs. Inlet Coolant Temperature


(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

 | Purchasing Guidelines


 

Product Glance Value
Model S19e XP Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical Hashrate, TH/s(2-1)
251 240
Power on wall @35°C(2-2), Watt(2-1)
5522 5280
Power efficiency on wall @35°C, J/TH(2-1) 22
Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(3-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware configuration
Network connection mode RJ45 Ethernet 10/100M
Server Size (length*width*height, w/o package), mm 410*170*209
Server Size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment requirements
Inlet coolant temperature, °C 20~50
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working Coolant(3-2) Antifreeze/ Pure water/Deionized water
Coolant pH Value Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized water:8.5~9.5
Diameter of Coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(2-2) Inlet coolant temperature.
(3-1) Caution: Wrong input voltage may cause server damaged.
(3-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

| Performance Curves
  1. Hashrate vs. Inlet Coolant Temperature   2. Power Efficiency vs. Inlet Coolant Temperature (1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.
 | Purchasing Guidelines
 
Product Glance Value
Model S19e XP Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical Hashrate, TH/s(2-1)
251 240
Power on wall @35°C(2-2), Watt(2-1)
5522 5280
Power efficiency on wall @35°C, J/TH(2-1) 22
Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(3-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware configuration
Network connection mode RJ45 Ethernet 10/100M
Server Size (length*width*height, w/o package), mm 410*170*209
Server Size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment requirements
Inlet coolant temperature, °C 20~50
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working Coolant(3-2) Antifreeze/ Pure water/Deionized water
Coolant pH Value Antifreeze: 7.0~9.0 Pure water: 6.5~7.5 Deionized water:8.5~9.5
Diameter of Coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%
Notes: (2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (2-2) Inlet coolant temperature. (3-1) Caution: Wrong input voltage may cause server damaged. (3-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!
0

Reviews

5
0
4
0
3
0
2
0
1
0
Be the first to review “Bitcoin Miner S19e XP Hyd.”

Leave a Reply

Your email address will not be published. Required fields are marked *

Compare similar items

Find and select products to see the differences and similarities between them

Customer Rating

(0)

(0)

(0)

(0)

Price
$2761.00
$84000.00
$1728.00
$3916.00
Item Dimensions
N/A
N/A
N/A
N/A
Special Features
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 251T 5522W 22J/T
Price
11 $/T
2,761 $/Unit
Shipping Date
Shipping in 10 working days after fully paid
Payment Method
USDBTCUSDT(ERC20/TRC20)
Specifications 1Set 1200kW 210 Rack Space
Price
84,000 $/Unit
Shipping Date
SPOT Shipping in 10 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(TRC20)
Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 288T 4896W 17J/T
Price
6 $/T
1,728 $/Unit
Shipping Date
SPOT Shipping in 20 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC2
Specifications 1028T 24kW I 4 S19 XP Hyd. and Rack I 45℃ Heating Capacity
Price
3,916 $/Package
Shipping Date
SPOT Shipping in 10 working days after fully paid
Payment Method
USDBTCETCUSDC(ERC20)USDT(ERC20/TRC20)
Weight
N/A
N/A
N/A
N/A
Availability

In stock

In stock

In stock

In stock